L282V01
L Series solenoid valve · 2/2 normally open
SIRAI L282V01, 2/2 normally open, pilot operated. For fluid shut-off or directional control. Select the configuration by connection, coil and service conditions; contact us to confirm price, lead time and availability.
Specifications
- Brand
- SIRAI
- Model
- L282V01
- Size / rating
- G 3/8 / G 1/2 / G 3/4 / G 1
- Material
- Brass
- Product configuration
- Pilot operated · 2/2 normally open
- Series
- SIRAI L Series · L282
- Function
- 2/2 normally open
- Seal material
- FPM
- Orifice diameter
- 13.5 / 18 / 24 mm
- Configuration 1
- G 3/8; orifice 13.5 mm; Kv 2.5 m³/h; min. Δp 0.35 bar; max. Δp: gas AC/DC 12/- bar, liquid AC/DC 12/- bar; PS 20 bar; fluid 0 to 130 °C; coil ZB10A
- Configuration 2
- G 3/8; orifice 13.5 mm; Kv 2.5 m³/h; min. Δp 0.35 bar; max. Δp: gas AC/DC -/12 bar, liquid AC/DC -/12 bar; PS 20 bar; fluid 0 to 130 °C; coil ZC10A
- Configuration 3
- G 1/2; orifice 13.5 mm; Kv 3.8 m³/h; min. Δp 0.35 bar; max. Δp: gas AC/DC 12/- bar, liquid AC/DC 12/- bar; PS 20 bar; fluid 0 to 130 °C; coil ZB10A
- Configuration 4
- G 1/2; orifice 13.5 mm; Kv 3.8 m³/h; min. Δp 0.35 bar; max. Δp: gas AC/DC -/12 bar, liquid AC/DC -/12 bar; PS 20 bar; fluid 0 to 130 °C; coil ZC10A
- Configuration 5
- G 3/4; orifice 18 mm; Kv 5 m³/h; min. Δp 0.35 bar; max. Δp: gas AC/DC 10/- bar, liquid AC/DC 10/- bar; PS 20 bar; fluid 0 to 130 °C; coil ZB10A
- Configuration 6
- G 3/4; orifice 18 mm; Kv 5 m³/h; min. Δp 0.35 bar; max. Δp: gas AC/DC -/10 bar, liquid AC/DC -/10 bar; PS 20 bar; fluid 0 to 130 °C; coil ZC10A
- Configuration 7
- G 1; orifice 24 mm; Kv 12 m³/h; min. Δp 0.35 bar; max. Δp: gas AC/DC 10/- bar, liquid AC/DC 10/- bar; PS 20 bar; fluid 0 to 130 °C; coil ZB10A
- Configuration 8
- G 1; orifice 24 mm; Kv 12 m³/h; min. Δp 0.35 bar; max. Δp: gas AC/DC -/10 bar, liquid AC/DC -/10 bar; PS 20 bar; fluid 0 to 130 °C; coil ZC10A
- Rating notes
- AC/DC denote supply types; “-” means not specified. PS is maximum allowable pressure, not the operating differential of every configuration. Confirm coil voltage, connections, media compatibility and application limits.
Please note: The specifications above are compiled from manufacturer published datasheets, official websites and other public sources, for reference only, and are not a basis for acceptance or inspection. Actual parameters, dimensions and configuration are subject to the latest manufacturer datasheet and the delivered goods; where any discrepancy exists, the manufacturer data shall prevail. Contact us if you need the original datasheet or confirmed data for ordering.